The measuring board Reflow V5 has eight thermocouples of the highest accuracy class. These are placed on specially designed measuring fields with excellent long-term stability and are optimized for the reflow soldering process. The measurement board Reflow V5 is designed to control the system parameters and their optimization in the reflow soldering system.
– 8 K-Type mineral insulated thermocouples
– DIN ISO 584 miniature connectors
– Determination of cross profile & thermal separation
– Determination of plant atmosphere
– Determination Influence of underheater
– Determination of gradients
– Determination of temperature difference
– Determination of heat transfer efficiency
– PTP® Shuttle can be integrated
– 3-fold integrated thermal protection
Specifications
8 K-Type mineral insulated thermocouples | |
Standard size (W x L) | 300 × 390 mm |
Max. temperature for 20 s | 350 °C |
Temperature long time | 280 - 300 °C |
Max. height with shuttle | <= 25 mm |
The measuring board Reflow V5 has eight thermocouples of the highest accuracy class. These are placed on specially designed measuring fields with excellent long-term stability and are optimized for the reflow soldering process. The measurement board Reflow V5 is designed to control the system parameters and their optimization in the reflow soldering system.
– 8 K-Type mineral insulated thermocouples
– DIN ISO 584 miniature connectors
– Determination of cross profile & thermal separation
– Determination of plant atmosphere
– Determination Influence of underheater
– Determination of gradients
– Determination of temperature difference
– Determination of heat transfer efficiency
– PTP® Shuttle can be integrated
– 3-fold integrated thermal protection